BR54.XXGB1PZKMAS.
VEGA VEGABAR 54 Ceramic Pressure Transmitter | BR54.XXGB1PZKMAS | -1 to 0 bar
Identify the right part for your application
Selected offer packaging
No packaging
VEGA VEGABAR 54 industrial ceramic-capacitive pressure transmitter (CERTEC / MINI-CERTEC family), manufacturer VEGA Grieshaber KG, Germany. Manufacturer product code: BR54.XXGB1PZKMAS. Order No.: 2145962/001. Serial No.: 31726256. MEASUREMENT AND SIGNAL Nominal measuring range: -1 to 0 bar (-100 to 0 kPa), relative/gauge vacuum pressure measurement. Analog output: 4-20 mA, 2-wire; nominal supply: 12-36 V DC. Accuracy class: 0.20% (characteristic deviation class, not total installed accuracy). The label specifies process pressure -1 to +50 bar; this is NOT the measuring range and should not be used as a substitute for the rated measuring span. PROCESS AND MECHANICAL G1/2 A front-flush stainless steel 316L process fitting (PN60 configuration), ceramic measuring diaphragm, FKM (Viton) seal. Process temperature: -20 to +120 degrees C. Standard ambient temperature range: -40 to +80 degrees C. Plastic housing with IP66/IP67 ingress protection and M20 x 1.5 cable entry. PLICSCOM display/adjustment is the code-listed option; verify the actual module fitted before representing it as included. ELECTRONICS (VEGABAR 54 4-20 mA operating manual) Maximum output current: 22 mA; signal resolution: 1.6 microA; typical start-up time: approx. 10 s; step response time: <=250 ms with damping at 0 s; configurable damping: 0-999 s; NAMUR NE43 recommendation. These are manufacturer-series specifications, not individual test or calibration results. ORDER CODE BREAKDOWN BR54: VEGABAR 54; XX: standard approval; GB: G1/2 A front-flush fitting, PN60, 316L; 1: FKM seal; P: -1 to 0 bar gauge range; Z: analog 4-20 mA electronics; K: plastic IP66/IP67 housing; M: M20 x 1.5 entry; A: PLICSCOM display option; S: 0.20% accuracy class. APPLICATIONS Industrial vacuum monitoring and compatible process pressure measurement in liquids and gases. Confirm suitability of the wetted materials, medium temperature and installation conditions for the intended process.
Product Type
Industrial Pressure Transmitter
Measurement Principle
Ceramic Capacitive
Measuring Cell
CERTEC / MINI-CERTEC
Pressure Measurement
Gauge / Vacuum
VEGA VEGABAR 54 industrial ceramic-capacitive pressure transmitter (CERTEC / MINI-CERTEC family), manufacturer VEGA Grieshaber KG, Germany. Manufacturer product code: BR54.XXGB1PZKMAS. Order No.: 2145962/001. Serial No.: 31726256. MEASUREMENT AND SIGNAL Nominal measuring range: -1 to 0 bar (-100 to 0 kPa), relative/gauge vacuum pressure measurement. Analog output: 4-20 mA, 2-wire; nominal supply: 12-36 V DC. Accuracy class: 0.20% (characteristic deviation class, not total installed accuracy). The label specifies process pressure -1 to +50 bar; this is NOT the measuring range and should not be used as a substitute for the rated measuring span. PROCESS AND MECHANICAL G1/2 A front-flush stainless steel 316L process fitting (PN60 configuration), ceramic measuring diaphragm, FKM (Viton) seal. Process temperature: -20 to +120 degrees C. Standard ambient temperature range: -40 to +80 degrees C. Plastic housing with IP66/IP67 ingress protection and M20 x 1.5 cable entry. PLICSCOM display/adjustment is the code-listed option; verify the actual module fitted before representing it as included. ELECTRONICS (VEGABAR 54 4-20 mA operating manual) Maximum output current: 22 mA; signal resolution: 1.6 microA; typical start-up time: approx. 10 s; step response time: <=250 ms with damping at 0 s; configurable damping: 0-999 s; NAMUR NE43 recommendation. These are manufacturer-series specifications, not individual test or calibration results. ORDER CODE BREAKDOWN BR54: VEGABAR 54; XX: standard approval; GB: G1/2 A front-flush fitting, PN60, 316L; 1: FKM seal; P: -1 to 0 bar gauge range; Z: analog 4-20 mA electronics; K: plastic IP66/IP67 housing; M: M20 x 1.5 entry; A: PLICSCOM display option; S: 0.20% accuracy class. APPLICATIONS Industrial vacuum monitoring and compatible process pressure measurement in liquids and gases. Confirm suitability of the wetted materials, medium temperature and installation conditions for the intended process.
In stock: 1